前往Shuct.Net首页

Shudepb PB反编译专家长时间以来,为业内同类软件事实上的唯一选择.细节,彰显专业.态度,决定品质.

关于PowerShield的搜索

Sentinel Power Reliable power for a sustainable world Worldwide Login Language Search Login GroupProductsUPSOnlineSentinel Pro (700 - 3000 VA)Sentinel Dual (Low Power) (1000 - 3000 VA)Sentinel Dual (High Power) (3.3 - 10 kVA)Sentinel Power Green (6 - 20 kVA)Sentinel Power (5 - 10 kVA)Multi Sentry (10 - 120 kVA)Multi Guard (120 kVA)Multi Guard Industrial (160 kVA)Master MPS (10 - 800 kVA)Master HP (100 - 600 kVA)Master HP UL (65 - 250 kVA)Master Industrial (30 - 80 kVA)Master FC400 (30 - 120 kVA)Line interactiveVFD TypeTransfer SystemsSolutionsSoftware & ConnectivityAreasEco Energy: efficiency levelUPS SmartGrid readyServicesSupportPress AreaContacts GroupThe Riello GroupOur roots and our historyBrand valuesEnergy and sustainabilityRiello UPS and DucatiReferences Products UPSOnlineSentinel Pro (700 - 3000 VA)Sentinel Dual (Low Power) (1000 - 3000 VA)Sentinel Dual (High Power) (3.3 - 10 kVA)Sentinel Power Green (6 - 20 kVA)Sentinel Power (5 - 10 kVA)Multi Sentry (10 - 120 kVA)Multi Guard (120 kVA)Multi Guard Industrial (160 kVA)Master MPS (10 - 800 kVA)Master HP (100 - 600 kVA)Master HP UL (65 - 250 kVA)Master Industrial (30 - 80 kVA)Master FC400 (30 - 120 kVA)Line interactiveNet Power (600 - 2000 VA)Vision (800 - 2000 VA)Dialog Vision (500 - 1100 VA)Vision Dual (1.1 - 3 kVA)VFD TypeiPlug (600 - 800 VA)iDialog (400 - 1600 VA) Transfer SystemsMulti SwitchMulti Switch ATSMaster Switch Single PhaseMaster Switch Three-phaseMaster Static Bypass (800 - 3000 kVA) SolutionsSuperCaps UPSMaster VDCPowerBoxCentral Supply Systems Software & ConnectivityPowerShield3PowerNetGuardNetman 101/102 plusNetMan 202 PlusEnvironmental sensorsMultiCOM 301/302MultiCOM 351/352MultiCOM 372MultiCOM 382MultiCOM 401Kit for AS400 and iSeries?Multi I/ORTG 100MultiPanel ServicesTEC TeamUPServiceRentTeleService SupportDownloadsFAQsCustomer Support Area Press AreaEventsNewsWhitepapersBlogNewsletterNewsletter Archive ContactsAddresses and contactsInformation RequestJob Opportunities UPSTransfer SystemsSolutionsSoftware & ConnectivityAreasEco Energy: efficiency levelUPS SmartGrid ready Products: UPSSentinel Power Power Range: 5 - 10 kVA 1:1 3:1 5-10 kVA SENTINEL POWER is the ideal solution for powering vital mission critical, sensitive loads such as electro-medical security applications in order to guarantee maximum reliability and availability. The series includes 5kVA-6kVA single/single phase and 6.5kVA-8kVA-10kVA single/single phase and three/single phase models and uses double conversion on-line technology (VFI). The load is powered constantly by the inverter which supplies filtered, stabilised and regulated sinewave voltage. Moreover, the input and output filters increase the immunity of the load against mains power disturbances and lightning strikes. SENTINEL POWER is without doubt one of the best UPS systems on the market today thanks to the technology used, the features (selectable Economy Mode and Smart Mode) and the diagnostics offered (custom LCD display, RS232 and USB interfaces complete with PowerShield&sup3; software, EPO contact and slots for optional interface boards). Tweet Request Information &raquo; Characteristics Downloads Related Products Technical Specifications HIGH UPS RELIABILITY &bull; Full microprocessor control. &bull; No break static and maintenance bypass. &bull; Features guaranteed up to 40&deg;C (the components are designed to operate at high temperatures and thus are subject to less stress at ordinary temperatures). SELECTABLE OPERATING MODES The operating mode can be programmed using the software or selected manually on the digital front panel display. &bull; On line Mode (VFI). &bull; Economy Mode: increases efficiency (up to 98%), and uses Line Interactive (VI) technology to power low priority loads from the mains supply. &bull; Smart Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending on the quality of the mains supply. &bull; Emergency Mode: the UPS can be set to operate only when mains power fails (emergency only mode). &bull; Frequency converter Mode (50 or 60 Hz). HIGH QUALITY OUTPUT VOLTAGE &bull; Even with distorting loads (IT loads with crest factor of up to 3:1). &bull; High short circuit current on bypass. &bull; High overload capacity: 150% on inverter, even when mains power fails. &bull; Filtered, stabilised and reliable voltage (double conversion on-line technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference). &bull; Rephasing of the load: UPS input power factor close to 1 with sinusoidal current absorption. SIMPLIFIED INSTALLATION &bull; The UPS can be connected to both single phase and three phase mains supplies. &bull; Output terminal board + 2 IEC plugs to power local equipment (computers, modems, etc.). &bull; Easy to move thanks to built-in wheels. HIGH BATTERY RELIABILITY &bull; Automatic and manual battery tests. &bull; Low Ripple Current Discharge system &ldquo;LRCD&rdquo; to prolong battery life. &bull; Unlimited extendable runtime thanks to dedicated modular design Battery Boxes. &bull; Increased ride-through for mains failures up to 40ms (high hold up time) and for fluctuations in the input current ranging from 84V to 276V). LOW IMPACT ON MAINS POWER &bull; Sinusoidal input current on single phase/single phase series. OTHER FEATURES &bull; Filtered, stabilised and reliable current (double conversion on-line technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference). &bull; Advanced diagnostics: status, measurements and alarms available on the custom LCD display &bull; Very low noise level (<40dBA): for installation in any environment thanks to the PWM digitally controlled ventilation that is load dependent, and the use of an inverter with high switching frequency (>20kHz, value above the audible range) &bull; Autorestart when mains power returns, can be programmed using software or the digital front panel display &bull; Emergency mode: the UPS can be programmed to work only when mains power fails (suitable for emergency lighting) &bull; Standard back feed protection: to avoid current being fed back into the mains system. &bull; Digital updating of the UPS (flash upgradable) ADVANCED COMMUNICATION &bull; Compatible with the Riello TeleNetGuard remote assistance system. &bull; Advanced, multi-platform communication for all operating systems and network environments: PowerShield&sup3; monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. &bull; RS232 serial port. &bull; Plug and Play connection. &bull; Slots for communication interface boards. Brochure Brochure Select File Language: en it de es fr hu zh ru PowerShield3 PowerShield&sup3; provides efficient, user-friendly UPS management using... PowerNetGuard PowerNETGuard software centralises UPS management using network interface... Netman 101/102 plus NetMan is an agent that enables UPS management and control across a LAN... NetMan 202 Plus The NetMan 202 plus network agent allows UPS directly connected over LAN... MultiCOM 301/302 The MultiCOM 301/302 protocol converter may be used to monitor the UPS... MultiCOM 351/352 The MultiCom 351/352 is a serial duplexer that allows two devices to be... MultiCOM 372 MultiCOM 372 provides a UPS with an additional RS232 serial interface... MultiCOM 382 MultiCOM 382 provides a set of relay contacts to provide UPS alarm and... MultiCOM 401 The MultiCOM 401 connects a Riello UPS to a Profibus DP Network. In... Multi I/O Multi I/O has configurable input and output signal contacts to allow UPS... Kit for AS400 and iSeries? Due to its single-level memory management feature, it is compulsory for... MultiPanel MultiPanel is a remote monitoring device that can provide a detailed UPS... Technical specifications of the model SPW 5000 SPW 6000 SPT 6500 SPT 8000 SPT 10000 Models SPW 5000 INPUT Rated power 5000 VA Voltage 220-230-240 Vac Voltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50% Frequency 50/60 Hz ± 5 Hz BY PASS Voltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode) Frequency tolerance Selected frequency ± 5% (user configurable) OUTPUT and INVERTER OUTPUT Rated power 5000 VA Active power 4000 W Crest factor (Ipeak/Irms) 3 : 1 Waveform Sinewave Frequency 50/60 Hz selectable Voltage distortion with distorcing load <6% Voltage distortion with linear load <3% OVERLOAD TIMES 100% < Load < 110% 1 min 125% = Load < 150% 4 s Load > 150% 0.5 s BATTERIES Typical recharge time 2÷4 h ENVIRONMENTAL Color Dark grey RAL 7016 Safety compliance EN 62040-1 and directive EEC 73/23 EMC conformance EN 62040-2 cl.B and directive 89/336 EEC, 92/31 EEC, 93/68 EEC Accessories provided software, 1 serial cable Protection rating 3 Communication slot RS232 + USB + remote contacts + communication interface slot Protections Overload - short-circuit - overvoltage - undervoltage - temperature - low battery Line-Interactive/Smart Active efficiency 98% Noise < 45 dBA at 1 m Operating temperature 0°C / +40°C Relative humidity < 95% non condensing DATA Weight 89 Kg Dimensions (h w d) 615x282x785 mm Back up time 16 min Contacts Addresses and contacts Information Request Support Downloads Services FAQs Customer Support Area Disclaimer Sitemap Terms of Use Copyright ? RPS Spa - Member of the Riello Elettronica Group - P.Iva IT02647040233 Web Agency