前往Shuct.Net首页

Shudepb PB反编译专家长时间以来,为业内同类软件事实上的唯一选择.细节,彰显专业.态度,决定品质.

关于PowerShield的搜索

Steve's Depot - Model Railroading, DCC & HOn3 Specialists 888-274-7677 info@stevesdepot.com ViewCart CheckOut About Us All Brands DCC DCC Info HOn3 G Sound Electronics Services Select DCC Brand Aux-BoxDCC SpecialtiesDigitraxESU (LokSound)LenzMRCNCE CorporationOlin's DepotPhoenix Sound SystemsQSISoundTraxxSPROGTrain Control SystemsTam Valley Depot Select DCC Brand -- Select Brand --Aux-BoxDCC SpecialtiesDigitraxESU (LokSound)LenzMRCNCE CorporationOlin's DepotPhoenix Sound SystemsQSISoundTraxxSPROGTrain Control SystemsTam Valley Depot DCC Specialties Home Power Management Power Supplies PowerShield X Circuit Breakers PowerShield X AC Breakers PowerShield X Auto-Reversers On-Guard! Circuit Breakers On-Guard! Auto-Reversers for Circuitron Tortoise Hare Stationary Decoders Wabbit Stationary Decoders Tortoise Buddy Layout Control Block Occupancy & Feedback Programming & Diagnostic Decoder Programming Diagnostic Meters DCC SpecialtiesPowerShield X Auto-Reversers The Power Shield X series is a product of years of research into problems dealing with false overload that cause premature shut down of DCC Boosters and other Circuit Breakers. These false overloads are caused by large capacitors used in sound systems decoders or lighted passenger cars. The overload appears as a short circuit until the capacitors are charged. The logic on the new Power Shield X Series determines if the load is a true short or just an overload due to discharged capacitor. The PSX-AR also has the logic and power to control switch machine(s) at the throat(s) of a reversing loop(s). Many other new features are also included. The PDF document linked here provides information comparing the On-Guard! and PowerShield (PSX) products. Features: All Solid State Operation Fast, solid state design with reliable quiet action. No clicks or sparks. DCC & AC Compatible Not just for use with DCC layouts, the PSX-AR is compatible with layouts using the newly introduced 2 Rail AC. Automatic Coordination of Auto Reverse and Circuit Breaker Tasks It is both a auto reverser and a circuit breaker. Adaptive Load Reset Electronically determines if the overload is a real short or due to excess capacitance in sound decoders or lighted passenger cars. Boost for Low Power Systems Some low power DCC Systems boosters need a boost when resetting. Adding this jumper helps reset low power output systems. Auto Stop with CV Reset A photocell input can detect a train in the reverse section and turn off power. A DCC command can then restore the power. Block Detection Either a photo cell or current can be used to detect a train in a block. The photocell can turn off the block. A DCC command can then restore the power. Over Voltage Protection If there is an over voltage on the track caused by a DCC System failure or other power inputs the PSX will shut down and protect decoders Wide Range of Current Trip Setting The currents can be adjusted over a range of 1.27 to 17.8 amps. Values can be set either with CV settings or Jumpers. Very Low Voltage Drop Breaker On resistance is less than 0.060 ohms, so the PSX has a low voltage drop even at high currents. Much better than detectors that use a diode voltage drop. Manual or Automatic Reset Automatic reset of the breaker after 2 seconds. A switch can be used for a manual reset. Power On/Off by DCC Turn on/off output track power with your DCC Throttle! Outputs for LED Indicators LEDs can be added to monitor the input/output power and the status. System Reset CV63=42 sets all CVs to original factory values. Output for Audio Alert An audible sounder can be added to the card to alert if there is a short. Board size 5.75 x 3.75 inches Flash Programmable Micro Processor can accept updated software if needed. No Power Supply Needed Model Description List Steve's Add Cart PowerShield Auto-Reversers (PSX-AR) with Integrated Stall Motor Decoder PSXAR PSX-AR All of the features listed above, plus: Automates Reverse Loop Turnouts Integrated Stall Motor Decoder, automatically lines up switch machines when the polarity is reversed. Switch machine can also be controlled with standard DCC Accessory Commands or push buttons. 64.95 53.95 PSXARFB PSX-ARFB All of the features of the PSX-AR, plus: Network Feedback Digitrax (LocoNet), Lenz (ExprssNet) and NCE (CabBus) for Occupancy and Shorted Status 69.95 59.95 PowerShield Auto-Reversers (PSX-AR) with Integrated Snap Coil Decoder PSXARSC PSX-ARSC All of the features listed above, plus: Automates Reverse Loop Turnouts Integrated Snap Coil Decoder, automatically lines up switch machines when the polarity is reversed. Switch machine can also be controlled with standard DCC Accessory Commands or push buttons. 77.95 65.95 PSXARSCFB PSX-ARSCFB All of the features of the PSX-ARSC, plus: Network Feedback Digitrax (LocoNet), Lenz (ExprssNet) and NCE (CabBus) for Occupancy and Shorted Status 79.95 68.95 Copyright © 2002-2014 Steve's Depot, LLC