前往Shuct.Net首页

Shudepb PB反编译专家长时间以来,为业内同类软件事实上的唯一选择.细节,彰显专业.态度,决定品质.

关于PowerShield的搜索

APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Support, Problems, Solutions & Manuals – Fixya Ask Solve Problems Search Sign In × Search Fixya: Search for solutions Press enter to search. × HomeUPS Battery Backup SystemsAPCPowerShield 24W 12VDC (cp24u12na3-f) UPS System For Businesses PRO × Troubleshooting & Support for APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Problems & Solutions RSS Feed where do I get PowerShield batteries Google Shopping results here. Leith UPS Battery Backup... Sep 16, 2013 8 Views 1 Solution not working when plugged only 3 of the 6 sockets have power when plugged to electrical outlet Most UPS's have split power. One is for Surge protected which is probably the half still working. The other come from a switching device called a relay. The relay is on the circuit board inside. If the battery backup'd half is dead, then that relaying is not connecting the power source to the three outlets. It could be due to a defective control circuit or the relay is bad. If you dont know electronics, either buy a whole new unit, or send it in for a rebuild with a place that knows what they doing. The manufacturers approved service places charge a reasonable price, but wont tell you anything for DIYers. I found a place in western canada that services them and does correspond with tips...that worked. And the obvious warning, the insides of a UPS can kill you if you dont take proper precautions Royal UPS Battery Backup... Jan 09, 2014 21 Views 1 Solution i need diagram for apc BK650M It's cheaper to get a new one then to try to fix these. Jh Sirois UPS Battery Backup... Oct 16, 2013 52 Views 2 Solutions pac makes continous sound What is the sound? Is the device working normally? Are there any lights or indicators? Do they indicate a fault or error?A UPS runs on standard 110-120 VAC power. It converts the input power to DC and charges internal batteries, then back to AC. Connected devices actually run on the conditioned 115-120 VAC output. The batteries serve as a short term backup power source.The electronics in the UPS can produce hum or high pitched tones. The sound should not be annoying. If it is louder than connected equipment (computers) it may indicate a problem. Hum is usually 60 Hz harmonics and difficult to eliminate. This harmonic may be transferred to audio equipment such as speakers or radios. A high pitched tone can be related to the rectifiers for the convertor/invertor. If the tone is loud, it means the rectifiers are drawing a lot of current. This is usually related to bad batteries.Measure the voltage on the output receptacles. It should be 115-120 VAC. Disconnect everything on the output receptacles. Unplug the UPS from it's power source. If the output power dies within 1 minute, the batteries need to be replaced. Glen Feldman UPS Battery Backup... Jul 19, 2012 697 Views 2 Solutions my apc ups cannot produce output Open it up and check the fuse. or your UPS may have a pop out fuse that may need to be reset Dennis Coej UPS Battery Backup... Sep 13, 2011 1111 Views 3 Solutions I have a BX1300G APC UPS. It will not turn on. If plugged in a socket the surge only outlets work fine. Took the fully charged battery from my BX1500G out and tried it in the 1300, still will not turn on. What now ? I'm lost. Help ! yes that means the inverter board is faulty. some component must be out of order probably a capacitor. inverter board is the one that converts your inserted battery DC power to AC which your system is using. you can either replace it or take to a service center and also if technical and with the right tools ( multimeter), identify the faulty component and replace it. Regards david_devore UPS Battery Backup... Oct 13, 2010 1231 Views 2 Solutions My APC RS 900 UPS is making a beeping noise and the red light on the front is blinking. It seems to be working, but what is it trying to tell me? Without knowing which light is flashing I can only guess. From my experience and assuming it is the battery light that is lit and NOT the overload light, it can be one of two things, one is your battery is near the end of its life and needs to be replaced, and the other is that your battery is improperly connected.To confirm if your battery needs to be replaced or not, you can run a self test. Ensure that the battery has had time to fully charge (and that it is definitely correctly connected), and then turn off the UPS, and turn it back on. It will automatically run a self test. if the light stays lit, you need to order new batteries. One source is here: http://www.refurbups.com/APC-Back-UPS-RS-900-BR900-Replacement-BatteriesIf it IS the overload light that is lit, you simply have too much equipment attached to the UPS, more than the inverter can handle. Try removing some equipment until it turns off. warrenh831 UPS Battery Backup... Mar 18, 2010 3434 Views 3 Solutions Both my APC UPS units switched to bypass at about the same time. There was no one in the room at the time, as per camera and access control logs. The technician said the units were switched off manually via the display panel. Is there an explanation? I do not believe Casper the Ghost did it! Thanks, Edwin B. there are several reasons that will make an ups to go to bypass, which include 1. overload, check the load percentages of your loads to make sure they dont exceed 100% . check logging events 2. ups failure, if the ups is set to go to bypass whenever it detects internal failure it will do so. but it is highly unlikey becouse they went to bypass at the same time. 3. manual bypass, somebody is involved in bypassing.for some ups system it is possible to see the cause of automatic bypassing, try and check in the user manual to see whether it is possible with your system. edwin_bringa UPS Battery Backup... Oct 17, 2009 777 Views 2 Solutions mge pulsar ex10 stop after 5 min with 60W charge,after I changed the pack of 3 bateries with one new.if I switch off and on works again 5 min. all 3 bateries are good,Vcharge=13,6v Vin use=12,3v thanks Some economics UPS have a functin called "Green Function". A timer disconnect the load after 5 min to prevent damages on internal circuit.You can confirm this:- battery remain to good level charge- UPS restart for other 5 min if you press On buttonSee manual if you can disable this features. yogi72cj UPS Battery Backup... Sep 28, 2009 275 Views 1 Solution APC SMARTUPS 1500VA Battery Problem When Replaced Hi! Am not a UPS guy so I need help from you guys. I have an APC SMARTUPS 1500 which I replaced the battery. When I turn it on, everything is good for about 10 seconds then all of a sudden, I get the Replace Battery light. Did a check on everything. all contacts are okay. I meter tested all contacts, voltages are ok, even the batteries. What do you think? Did I miss out on something? You are correct. The APC Smart line has a partial charge when it's new. Similar to cordless phones, the work right away, but you're still supposed to charge them before use for best results.Just leave it plugged in with no load for a couple hours and it will be fine. Peter Timbol UPS Battery Backup... Sep 02, 2009 1749 Views 2 Solutions Hi, I plugged in unit and continued to get a battery not connected in the LED window. After letting it run for 2-3 hours, I selected to power down the matrix unit. I noticed hearing a fan about an hour later and went into the office to check it out-fan was running on the bottom unit. Now I can not get the LED screen to show anything on it. I though it might be cycling process. after trying for 2 days and no success I am at the end of rope and can over ride by turning it off at the circuit breaker. Really trying to find out the problem Is the UPS more than 2 years old?The batteries in the UPS may have died. Get APC to check it out and they can supply replacement batteries. joe5548 UPS Battery Backup... Sep 10, 2009 352 Views 1 Solution Dear Sir i will like to ask you if it is possible to change or reset the actually password-protector that have an UPS APC Silcon SL60KF with a master password or reset and for this the ups recover the fabric password I have had the problem of APC's PowerChute software forgetting my password. No joke. I write these things down when I set them. Two options: Call APC support. They are awesome. Smart, well spoken and free. You will need the model number and serial number from your UPS. (800) 555-2725 Remove and reinstall the APC software. During the reinstallation you should be prompted to set a new password. Vote for this solution if it helps. ingenieria UPS Battery Backup... Aug 17, 2009 320 Views 1 Solution overload continus beeping sound This likely indicates too many appliances plugged into the UPS. More than the UPS can handle, so an overload condition is likely present. Try removing some devices from the UPS and see if it corrects the problem. If not, sometimes when you overload these smaller units they don;t take it so well, and something internal might have popped, if that's the case, start shopping for a replacement. http://www.gowithon.com mazhar865 UPS Battery Backup... Jun 08, 2009 1140 Views 1 Solution I have a apc 650 model bk650mus battery backup. when power is cut the battery doesn't seem to work. (no power coming from the apc unit. i thought i just needed a new battery but i pulled it out of the unit and checked the voltage and i'm getting 13.5dcv. i'm not sure what voltage i should be getting but i assumed that it's probabably a 12v battery? any suggestions on correct batt voltage or what else i can look at on the unit that may be faulty? how long the lifespam is the battery you had are using it? if you check the voltage that is 13.5dcv but it could be the Ah is already running low.. try to change with a new batts and power up the ups ifi it not workin that mean it the hardware issue.. shawn_patrik UPS Battery Backup... Mar 23, 2009 372 Views 1 Solution Smart UPS SUA1000i alarm with "overload" on zero load. UPS on powering up does self-test and immediately switch to overload alarm (even with no load connected. I have tested all 8 MOSFET - all are OK. Nothing is burned on the board. trafo on bord, or relay Reuel Teoh UPS Battery Backup... Jan 07, 2014 5 Views 1 Solution Popular Tags: beeping red light reset battery beep dead circuit red light 1000 ph buzz smart circuit diagram schematic batteries diagram battery lights 1000 reboot beeps charging battery back outage schematic igbt 1000 batteries... bx900r back pro warranty unit orange led 1500 350 back See all APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Related Problems APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Tips & How Tos Tips & tricks from the Fixya community. Asking Ultra Products For Battery Change Support Under Its Limited Lifetime Warranty Radio Interference affecting the UPS Flash From a Cameras on 3 Phase UPS MGE battery timer reset. 3000,6000 galaxy, comet Universal Power Supplies Uninterruptible Power Supply Faults UNINTERRUPTIBLE POWER SUPPLY UPS - Battery Fault Have a tip for APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System? Submit a Tip (+5pts) Related UPS Battery Backup Systems Videos: What's causing the beeping and the... Lightning struck the main switch... Product price View All UPS Battery Backup Systems Videos APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Unsolved Problems RSS Feed My APC Power Shield is My APC Power Shield is beeping about every 5 minutes. I have 2 solid green lights and the far right... Answer This cyndi_luna UPS Battery Backup... Feb 11, 2011 104 Views APC PowerShield beeps every 5 APC PowerShield beeps every 5 minutes. light on right is on solid red. I push it (seems to also be... Answer This mjohnson65 UPS Battery Backup... Oct 19, 2010 292 Views making a sound and battery display Answer This Guest UPS Battery Backup... Feb 13, 2014 11 Views bluetooth vox340 where to find the replacement battery Answer This Guest UPS Battery Backup... Feb 09, 2014 Hello, I am looking for a schematic diagram for APC 650... Answer This Guest UPS Battery Backup... Jan 31, 2014 14 Views exide 650va power button faills Answer This rono philiph UPS Battery Backup... Jan 31, 2014 11 Views cold solder joint Answer This Guest UPS Battery Backup... Jan 24, 2014 extended run time battery power solutions Answer This Guest UPS Battery Backup... Jan 22, 2014 UPS shuts off My computer UPS shuts off when the power comes and not the power goes off Answer This Guest UPS Battery Backup... Jan 22, 2014 24 Views measure rms voltage Answer This Guest UPS Battery Backup... Jan 21, 2014 See all APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Unsolved Problems APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Manuals & Guides http://sturgeon.apcc.com/techref.nsf/partnum/990-0375F/$FILE/990-... PDF Have a manual for APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System? Or just drag it anywhere on this box! APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Tech Specs Key Features Full Product Name APC PowerShield 24W 12VDC (cp24u12na3-f) UPS System Platform PC Form Factor Desktop Output Power (VA) 24 VA Output Power (W) 24 W Max Backup Time With Full Load 168.6 Minutes Technical Features Surge Suppression Without Surge Suppression Automatic Shutdown Without Automatic Shutdown Audible Alarm Without Audible Alarm Cable Length 8 ft. Dimensions Depth 3 in. Width 9.5 in. Weight 7.5 lb. Ask about this product Add to My Products Remove from My Products 1,161 people viewed this product 1,161 people have viewed this category //--> 4 people asked about this product. 1 person found solutions for this product. 0 people have added this product. Be the first! Ask a Fixya Expert: Problem title: Did you mean? Yes No Question details: Top APC UPS Battery Backup Systems Experts 2 Eric Pettingill Solutions: 141 Points: 171 Level: 2 Achievements: 2 2 Jesrey Paco-in Solutions: 77 Points: 112 Level: 2 Achievements: 2 3 Chris Hingee Solutions: 32281 Points: 101627 Level: 3 Achievements: 5 Are you an APC UPS Battery Backup System Expert? Answer questions and help others. View Most Popular APC UPS Battery Backup Systems APC UPS Battery Backup Systems Most Popular Problem get PowerShield batteries UPS Battery Backup Systems where do I get PowerShield batteries APC UPS Battery Backup Systems beeping APC Smart-UPS 1000VA UPS System What's causing the beeping and the... My APC Power Shield is APC Back-UPS ES 350 - UPS ( external ) - 350 VA - UPS... not working when plugged only 3 of the 6 sockets have... red light UPS Battery Backup Systems APC Back-UPS CS 500VA UPS System reset battery prev next next prev About Fixya Advertising Blog Careers Contact FAQ News & Media Our Company Partners Privacy Policy Terms Quick Links Answer Questions Ask a Question Fixboard Fixya Reports Find Products Fixya Pro Fixya Mobile Apps Popular & New Recent Problems & Solutions Tags Top Experts Videos Popular Categories Automotive Baby & Toddler Computers & Accessories Electronics Health & Beauty Home & Garden Office Equipment Sports & Outdoors Tools & Hardware Related Links Troubleshooting for most common APC UPS Battery Backup System productsMost common topics for PowerShield 24W 12VDCSee other APC UPS Battery Backup SystemsSee other APC productsSee other Computer Accessories productsRecent SolutionsRecent Problems Back to Top Join Fixya on Google+ Follow Fixya on Twitter Join Fixya on Facebook By entering the Fixya site you declare that you have read and agreed to its Terms. You may NOT copy or distribute the content that appears on this site without written permission from Fixya Ltd. © 2005-2014, Fixya, Ltd. or it's affiliates. Loading... Oops :Please try again.